Products
The main technical parameters:
Product Type: DA21F-25 / 40T
Nominal diameter: DN8
Nominal pressure: 2.5MPa, 4.0MPa
Applicable temperature: -196 ℃ ~ +80 ℃
Applicable medium: liquid oxygen, liquid nitrogen, liquid argon, liquid and so on.
Connection form: thread
Main material: H62
Applications and features:
Low temperature safety valve is widely used in a variety of pressure piping systems, from the security protection. I produced the low-temperature safety valve low temperature sealing performance, stable performance, open sensitive to ensure the safe operation of low-temperature equipment. If the use of toxic, explosive, should use the structure with a bellows.
Use and maintenance precautions:
1, the installation should pay attention to the media flow;
2, installation orientation: vertical installation;
3, before installation should pay attention to ensure that the pipeline blowing clean;
4, the valve degreasing treatment, storage, installation should pay attention to keep clean;
5, after the completion of pipeline construction, the pipeline should be all open the valve, repeated thoroughly blown away the pipe residue to ensure that the pipeline system clean no debris;
6, found the valve flap, seat, stem and other precision parts of the wear or damage, the need for timely repair or replacement;
7, safety valve at least once a year check.
Note: When installed on the oxygen pipe, avoid oil.